EUCHNER Locking set MGB-L1HE-APA-R-112601; 112601
Locking set MGB-L1HE-APA... (guard locking by spring force) without controls or indicators, RC18, on mounting plates Guard locking with guard lock monitoring With...
Price on request
Locking set MGB-L1HE-APA... (guard locking by spring force) without controls or indicators, RC18, on mounting plates
- Guard locking with guard lock monitoring
- With plug connector RC18
- Mounted on mounting plates
- With escape release
- Unicode
Approvals



Escape release MGB-E-A2-106051 (Order no. 106051)

Mechanical values and environment
| Installation orientation | any |
| Mechanical life | 1 x 10⁶ |
| Ambient temperature | -25 ... +55 °C |
| Material | |
| Housing | Die-cast zinc/stainless steel, powder-coated |
Miscellaneous
| Product version number | V2.0.0 |
| Additional feature | with mounting plate |
Handle modules MGB-H-AA1A6-R-111838 (Order no. 111838)

Mechanical values and environment
| Installation orientation | Door hinge DIN right |
| Degree of protection | IP65 |
| Ambient temperature | -20 ... +55 °C |
| Material | |
| Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
| Product version number | V3.0.0 |
| Additional feature | with mounting plate and automatic lockout mechanism |
Locking modules MGB-L1-APA-AA1A2-S1-R-112597 (Order no. 112597)

Operating and display elements
| Occupancy diagram | L0 |
Electrical connection values
| Rated insulation voltage Ui | 30 V |
| Rated impulse withstand voltage Uimp | 1.5 kV |
| Discrepancy time | |
| between FO1A and FO1B | max. 10 ms |
| Utilization category | |
| DC-13 | 24V 200mA |
| Risk time according to EN 60947-5-3 | max. 350 ms |
| Safety class | III |
| Transponder coding | Unicode |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Solenoid control input IMP1, IMP2, IMM | |
| Test pulse duration | max. 5 ms |
| Test pulse interval | min. 100 ms |
| Monitoring outputs OD, OT, OL, OI | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | UA-2V ... UA V DC |
| Output current | max. 50 mA |
| Safety outputs FO1A, FO1B | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| UFO1A /UFO1B LOW | 0 ... 1 V DC |
| UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
| Output current | |
| per safety output FO1A / FO1B | 1 ... 200 mA |
| Test pulse duration | max. 0.3 ms |
| Test pulse interval | min. 100 ms |
| Power supply UA | |
| Operating voltage DC | |
| UA | 24 V DC -15% ... +10% |
| Current consumption | |
| IUA | max. 375 mA |
| Power supply UB | |
| Operating voltage DC | |
| UB | 24 V DC -15% ... +10% |
| Current consumption | |
| IUB | max. 80 mA |
Mechanical values and environment
| Connection type | Plug connector RC18 |
| Installation orientation | Door hinge DIN right |
| Switching frequency | 0.25 Hz |
| Mechanical life | |
| 1 x 10⁶ | |
| in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
| Degree of protection | IP65 |
| Ambient temperature | |
| at UB = 24 V DC | -20 ... +55 °C |
| Material | |
| Housing | Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel |
| Locking force FZh | 2000 N |
| Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| Mission time | 20 y |
| Control of guard locking | |
| Category | 4 |
| Performance Level | PL e |
| PFHD | 2.8 x 10-9 |
| Monitoring of guard locking and the guard position | |
| Category | 4 |
Similar products:
EUCHNER Locking module MGB-L1-APA-AB6A1-S1-R-109764; 109764
Locking module MGB-L1-APA.., (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-

(Out of stock)
Price on request
EUCHNER Locking module MGB-L2-APA-AC6A1-S1-R-110500; 110500
Locking module MGB-L2-APA.., (guard locking by solenoid force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-

(Out of stock)
Price on request
EUCHNER Locking module MGB-L1-APA-AC6A1-S1-R-110498; 110498
Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-

(Out of stock)
Price on request
EUCHNER Locking set MGB-L1H-APA-R-121377; 121377
Locking set MGB-L1H-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-

(Out of stock)
Price on request
EUCHNER Locking set MGB-L1H-APA-R-121369; 121369
Locking set MGB-L1H-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-

(Out of stock)
Price on request
EUCHNER Locking set MGB-L1H-APA-R-116428; 116428
Locking set MGB-L1H-APA... (guard locking by spring force) with 3 pushbuttons, incl. label carrier, M12 for enabling switch, RC18 Guard locking with guard lock monitoring
-

(Out of stock)
Price on request