EUCHNER Safety Relays


Search by features
Sort products by
Brand
  • 23
Price up to
In stock
  • 0
OPERATING VOLTAGE
  • 17
  • 6
NUMBER OF SAFETY CONTACTS
  • 6
  • 11
  • 4
  • 2
AUXILIARY CONTACTS
  • 10
  • 13


EUCHNER Safety Relays


The EUCHNER safety relays series ESM ensure that the safety circuits are interrupted. For one thing, they safely evaluate components connected, and for another, they safely shut down dangerous machine functions.

EUCHNER Safety Relay ESM-ES303 ; 085616

Contact expansion ESM-ES.., 3 safety contacts, 1 auxiliary contact, cat. 4 Usage up to category 4 according to EN ISO 13849-1 LED status indicators Control using
-
Need to order

(Out of stock)

Price on request

EUCHNER Safety Relay ESM-2H201 ; 085620

Safety relay ESM-2H.. ,Type IIIc evaluation unit for two-hand control Usage up to category 4 according to EN ISO 13849-1 Requirement level IIIC according to EN 574
-
Need to order

(Out of stock)

Price on request

EUCHNER Safety Relay ESM-BT421 ; 090820

Basic device ESM-BT.., 4 safety contacts, time-delay, cat. 4 Usage up to category 4 according to EN ISO 13849-1 LED status indicators 1-channel or 2-channel control
-
Need to order

(Out of stock)

Price on request

EUCHNER Safety Relay ESM-BT401 ; 090818

Basic device ESM-BT.., 4 safety contacts, time-delay, cat. 4 Usage up to category 4 according to EN ISO 13849-1 LED status indicators 1-channel or 2-channel control
-
Need to order

(Out of stock)

Price on request

EUCHNER Safety Relay ESM-BT411 ; 090819

Basic device ESM-BT.., 4 safety contacts, time-delay, cat. 4 Usage up to category 4 according to EN ISO 13849-1 LED status indicators 1-channel or 2-channel control
-
Need to order

(Out of stock)

Price on request

EUCHNER Safety Relay ESM-BT421-50S ; 090094

Basic device ESM-BT.., 4 safety contacts, time-delay, cat. 4 Usage up to category 4 according to EN ISO 13849-1 LED status indicators 1-channel or 2-channel control
-
Need to order

(Out of stock)

Price on request

EUCHNER Safety Relay ESM-BA701P ; 097225

Basic device ESM-BA7.., 7 safety contacts, 4 auxiliary contacts, 2 signaling contacts, cat. 4 ESM-BA.. Usage up to category 4 according to EN ISO 13849-1 LED status
-
Need to order

(Out of stock)

Price on request

EUCHNER ESM-BA701 ; 097224

ESM-BA.. Usage up to category 4 according to EN ISO 13849-1 LED status indicators 1-channel or 2-channel control 7 redundant safety contacts 4 auxiliary contacts
-
Need to order

(Out of stock)

Price on request


Page 2 od 2
Showing 16 - 23 od 23 data

EUCHNER Safety Relays


For machines and installations that can produce a risk for people when in operation, the EU Machinery Directive defines minimum requirements that are intended to reduce to a minimum the specific hazards and the
related risks of accident.
If all sources of danger cannot be eliminated by design measures, appropriate protective measures must be taken. Using guards, such as fences or similar, it is intended to prevent personnel from entering the danger
area. If users need to have access to the danger area during operation, movable guards such as safety doors, flaps, etc., are used. This is the case, for example, for loading or unloading, troubleshooting, machine
setup or cleaning work.
To safeguard this access area, safety switches with various principles of operation are used. These switches are designed to monitor the position of the guard and, when the guard is opened, to generate a signal that will
safely interrupt the supply of power to the potentially hazardous parts of the installation or that will ensure that the safety circuits are safely interrupted.
The EUCHNER safety relays series ESM ensure that the safety circuits are interrupted. For one thing, they safely evaluate components connected such as
-- mechanical safety switches with and without guard locking,
-- non-contact safety switches,
-- emergency stop controls,
-- electro-sensitive protective equipment, etc.,
for another, they safely shut down dangerous machine functions.
The safety relays impress with their compact mounting rail housing and their suitability for applications up to category 4/PLe according to EN ISO 13849-1.


Brochure:
Safety Relays ESM
Applications:
Connection of MGB2 Classic and CES-C07 in Series to Safety Relay ESM-BA..1
Connection of CTM-LBI-BR-.. to Safety Relay ESM-BA..1
Connection of CTM-LBI-BP-.. to Safety Relay ESM-BA..1 from V1.0.0
Connection of CTP/CTA-L.-B.-.. to Safety Relays ESM-BA..1 from V1.0.0
Instructions:
Operating Instructions Safety Relay ESM-BL2..
Operating Instructions Safety Relay ESM-BA2..
Operating Instructions Safety Relay ESM-BA3..
Operating Instructions Safety Contact Expansion ESM-ES3..
Operating Instructions Safety Contact Expansion ESM-TE3..
Operating Instructions Safety Relay ESM-BA7..
Operating Instructions 2-Hand Safety Relay ESM-2H2..
Operating Instructions Safety Relay ESM-BT4..

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products