Multifunctional Gate Box


Search by features
Sort products by
Brand
  • 369
Price up to
In stock
  • 0
GUARD LOCKING DEVICE
  • 5
  • 5
  • 1
  • 311
  • 47
HINGE POSITION
  • 16
  • 158
  • 195
DESIRED CONNECTION
  • 15
  • 137
  • 176
  • 18
  • 15
  • 4
  • 4
CATEGORY
  • 9
  • 86
  • 267
  • 5


Multifunctional Gate Box


MGB-AP for use as a single device; MGB-AR for series connection up to 10 MGB-AR devices; MGB-PN for Profinet connection; MGB Ethernet/IP for Ethernet connection.

EUCHNER Locking module MGB-L1C-ARA-L-156859; 156859

Locking module MGB-L1-ARA..., (guard locking by spring force) with 5 pushbuttons, emergency stop, incl. label carrier, RC26 Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking module MGB-L1C-ARA-R-156858; 156858

Locking module MGB-L1-ARA..., (guard locking by spring force) with 5 pushbuttons, emergency stop, incl. label carrier, RC26 Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1HE-APA-R-122089; 122089

Locking set MGB-L1HE-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1HE-APA-L-122090; 122090

Locking set MGB-L1HE-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L2HE-APA-L-110522; 110522

Locking set MGB-L2HE-APA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop, key-operated rotary switch, incl. label carrier, RC18, IP42 Guard
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L2HE-APA-R-110521; 110521

Locking set MGB-L2HE-APA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop, key-operated rotary switch, incl. label carrier, RC18, IP42 Guard
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1HE-ARA-R-157888; 157888

Locking set MGB-L1HE-ARA... (guard locking by spring force) with 1 pushbutton, emergency stop, M12 for enabling switch, RC26 Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1HE-ARA-L-157890; 157890

Locking set MGB-L1HE-ARA... (guard locking by spring force) with 1 pushbutton, emergency stop, M12 for enabling switch, RC26 Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1HE-APA-L-158120; 158120

Locking set MGB-L1H-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1HE-APA-R-158118; 158118

Locking set MGB-L1H-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1HC-ARA-R-156860; 156860

Locking set MGB-L1H-ARA..., (guard locking by spring force) with 5 pushbuttons, emergency stop, incl. label carrier, RC26 Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1HC-ARA-L-156861; 156861

Locking set MGB-L1H-ARA..., (guard locking by spring force) with 5 pushbuttons, emergency stop, incl. label carrier, RC26 Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB2-L1H-MLI-U-DA-L-162535; 162535

Locking set MGB2-L1... (2 pushbuttons, emergency stop, closed-circuit current principle, door hinge on left) Guard locking with guard lock monitoring Illuminated
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1HC-ARA-L-109807; 109807

Locking set MGB-L1H-ARA... (guard locking by spring force) with 3 pushbuttons, 2 indicators, emergency stop, incl. label carrier, RC26 Guard locking with guard lock
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L2HC-ARA-L-112532; 112532

Locking set MGB-L2H-ARA... (guard locking by solenoid force) with 3 pushbuttons, 2 indicators, emergency stop, incl. label carrier, RC26 Guard locking with guard
-
Need to order

(Out of stock)

Price on request


Page 24 od 25
Showing 346 - 360 od 369 data

Multifunctional Gate Box


The MGB is a safety system with guard locking and guard lock monitoring for the protection of safety doors on machines and installations.

Economical, standard-compliant wiring

The family MGB-AP is particularly suitable for the protection of individual safety doors. If series connection is not necessary, wiring can then be saved. This version has different timing to the AR version.
All devices in the family MGB-AR can be wired directly in series in a so-called AR series connection without reducing safety or the PL. As a consequence evaluation units are saved.
AR devices are also available in the EUCHNER series CES and CET.

Seamless integration by means of bus connection

In the PROFINET version, MGB-PN, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary PROFINET input and output bytes required. Comprehensive diagnostic information in the form of PROFINET messages makes troubleshooting quick and specific. Due to the typical ease with which parameters can be set in PROFINET, even the replacement of the system in case of servicing is a simple matter and can be undertaken in a few minutes.

In the MGB Ethernet/IP™ version, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary CIP Safety input and output bytes required. Whether interlocking, guard locking, escape release or other functions such as buttons for start/stop, emergency stop, selector switch, etc. – the MGB meets all requirements for safety-related applications and can be equipped on a customer-specific basis. Comprehensive diagnostic information in the form of Ethernet/IP™ messages provides a fast and detailed overview of the device status. Due to the ease with which parameters can be set, even replacing the system during servicing is a simple matter and takes no more than a few minutes.



---------- Documents ----------
MGB
Catalogs:

Multifunctional Gate Box MGB
Instructions:
Operating Instructions Safety Systems MGB-L0…-AR.-… and MGB-L0…-AP.-…
Operating Instructions Safety Systems MGB-L1…-AR.-… / MGB-L2…-AR.-… and MGB-L1…-AP.-… / MGB-L2…-AP.-…
Operating Instructions Safety Systems MGB-L..B-EI-… (Ethernet/IP) and With Data Structure Type A From V1.5.0
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type A
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type B
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type C (Expanded)
Operating Instructions Safety Systems MGB-B-…-PN (PROFINET) and With Data Structure Type C (Expanded)
Safety information
Applications:
Connection of MGB-L1..-AP to Safety Relay ESM-BA..1
Connection of MGB-L1..-AP to Siemens ET 200S
Connection of MGB-L1..-AP to Siemens ET 200S

Connection of MGB-L1..-AR to Siemens ET 200S
Connection of serial wired MGB-L1..-AR to Siemens ET 200S
Connection of MGB-L1..-AR to Safety Relay ESM-BA..1
Connection of serial wired MGB-L1..-AR and CET3-AR to Siemens ET 200S
Connection of serial wired MGB-L1..-AR, CES-AR and CET3-AR to Siemens ET 200S
Examples for Use of the MGB Inputs and Outputs

Connection of MGB-L2..-AR to safety relay PNOZ X3.10P
Connection of MGB-L2..-AR to safety relay PNOZ s5
Connection of MGB-L1..-AR to a safety relay MSR127TP
Connection of serial wired MGB-L1..-AR to Safety Relay MSR127TP

Connection of MGB-L1B-EI… to Allen Bradley ControlLogix
AOI for MGB-L1B-EI… on Allen Bradley ControlLogix
MGB-L1B-EI… on Allen Bradley ControlLogix with Gateway in Network
Replacement of an MGB Ethernet/IP System
MGB-EIP – IP Address Assignment with BOOTP/DHCP
Connecting MGB-L1B-EI... to Allen Bradley ControlLogix from V1.5
Connection of MGB-L1B-EI... to OMRON Sysmac Studio® from V1.45

Connection of MGB-L2B-PN… to Siemens S7 315F
Connecting MGB-L1B-PN… to Siemens S7 315F (TIA Portal V13)
Replacement of an MGB System Without Programming Device

Flyers:
Keeping a handle on everything! Multifunctional Gate Box MGB (PDF)

MGB2
Catalogs:
Multifunctional door locking systems MGB2
Instructions:
Operating Instructions Interlocking/Locking Modules MGB2-I..-MLI-... / MGB2-L..-MLI-... (Modular)
Operating Instructions Safety Systems MGB2-L1…-BR.-… / MGB2-L2…-BR.-… and MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
Operating Instructions Safety Systems MGB2-I-BP.-… / MGB2-I-BR.-…
Operating Instructions Interlocking/Locking Modules MGB2-I..-MLI-... / MGB2-L..-MLI-... (Modular)
Operating Instructions Bus Module MBM-PN-..-MLI-… (PROFINET) up to V1.5.X
Operating Instructions Expansion Module MCM-MLI... up to V1.2.X
Operating Instructions Submodule MSM-1-R-CKS2-FLX-...
Operating Instructions Bus Module MBM-PN-..-MLI-… (PROFINET) up to V1.5.X
Operating Instructions Safety Systems MGB2-L..B-PN.-… (PROFINET)
ATTENTION! Temporary change in the technical data.
Operating Instructions Bus Module MBM-PN-..-MLI-… (PROFINET)
Applications:
Integration of MGB2 Modular EtherCAT in Beckhoff TwinCAT 3 from V1.0.0
Connection of MGB2 Classic to safety relay ESM-BA..1
Connection of MGB2 Classic and CES-C07 in Series to Safety Relay ESM-BA..1
Connection of MGB2-L.-B.-... Classic to Siemens ET 200SP
Integration of MGB2 Modular into TIA Portal V13/V14/V15
Integration of MGB2 Modular in Beckhoff TwinCAT 3 From V1.5.8
Integrating MGB2 Modular in STEP 7 V5.5
Replacement of an MGB System Without Programming Device
Connection of MGBS-P-L1-AR-.. to Safety Relays ESM-BA..1
Flyers:
Door locking systems MGB2 Classic and MGB2 Modular (PDF)
MGB2 Modular (PDF)
MGB2 Classic (PDF)

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products