Base unit (BU30-MS7) With F-DI infeed For ET 200SP motor starter With infeed 500 V Incl. infeed bus cover...
Price on request
| Base unit (BU30-MS7) With F-DI infeed For ET 200SP motor starter With infeed 500 V Incl. infeed bus cover |
| product brand name | SIMATIC |
| product category | Accessories |
| product designation | BaseUnit |
| design of the product | with AC infeed, with F-DI infeed |
| product type designation | ET 200SP |
| General technical data | |
| insulation voltage rated value | 500 V |
| degree of pollution | 2 |
| surge voltage resistance rated value | 6 kV |
| maximum permissible voltage for safe isolation | |
| ● between main and auxiliary circuit | 500 V |
| shock resistance | 6g / 11 ms |
| vibration resistance | 15 mm to 6 Hz; 2g to 500 Hz |
| reference code according to IEC 81346-2 | Q |
| Substance Prohibitance (Date) | 04/15/2016 |
| Safety related data | |
| protection class IP on the front according to IEC 60529 | IP20 |
| touch protection on the front according to IEC 60529 | finger-safe |
| Main circuit | |
| number of poles for main current circuit | 3 |
| type of voltage of the operating voltage | AC |
| operating voltage rated value | 500 V |
| operating voltage of AC supply | 500 V |
| operational current at AC at 400 V rated value | 32 A; Derating, see Manual |
| Inputs/ Outputs | |
| number of digital inputs | 1 |
| type of input characteristic | Type 1 in accordance with EN 61131-2 |
| input voltage at digital input | |
| ● at DC rated value | 24 V |
| ● with signal <0> at DC | 0 ... 5 V |
| ● for signal <1> at DC | 15 ... 30 |
| Supply voltage | |
| type of voltage of the supply voltage | DC |
| supply voltage 1 at DC rated value | 24 V |
| ● minimum permissible | 20.4 V |
| ● maximum permissible | 28.8 V |
| ampacity maximum | 7 A |
| Installation/ mounting/ dimensions | |
| mounting position | vertical, horizontal |
| fastening method | DIN rail |
| height | 215 mm |
| width | 30 mm |
| depth | 75 mm |
| required spacing with side-by-side mounting | |
| ● upwards | 50 mm |
| ● downwards | 50 mm |
| Ambient conditions | |
| installation altitude at height above sea level maximum | 4 000 m; For derating see manual |
| ambient temperature | |
| ● during operation | -25 ... +60 °C; For derating see manual |
| ● during storage | -40 ... +70 °C |
| ● during transport | -40 ... +70 °C |
| environmental category during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices) |
| relative humidity during operation | 10 ... 95 % |
| air pressure according to SN 31205 | 900 ... 1 060 hPa |
| Connections/ Terminals | |
| type of electrical connection | |
| ● for main current circuit | spring-loaded terminals (push-in) |
| ● for auxiliary and control circuit | spring-loaded terminals (push-in) |
| type of connecting terminal | Push-in terminal |
| type of connectable conductor cross-sections for supply | |
| ● solid | 1x 1 ... 6 mm² |
| ● finely stranded without core end processing | 1x 1 ... 6 mm² |
| ● finely stranded with core end processing | 1x 1 ... 6 mm² |
| type of connectable conductor cross-sections | |
| ● at AWG cables for supply | 1x 18 ... 10 |
| type of connectable conductor cross-sections for load-side outgoing feeder | |
| ● solid | 1x 0,5 ... 2,5 mm² |
| ● finely stranded without core end processing | 1x 0,5 ... 2,5 mm² |
| ● finely stranded with core end processing | 1x 0,5 ... 2,5 mm² |
| type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder | 1x 20 ... 12 |
| connectable conductor cross-section at DC input | |
| ● single or multi-stranded | 0.5 ... 2.5 mm² |
| ● finely stranded without core end processing | 0.5 ... 2.5 mm² |
| ● finely stranded with core end processing | 0.5 ... 2.5 mm² |
| AWG number at DC input as coded connectable conductor cross section | 20 ... 12 |
| shape of the screwdriver tip | Slot |
| size of the screwdriver tip | Standard screwdriver 0.6 mm x 3.5 mm |
Similar products:
Siemens ET 200SP, BU F-DI -infeed; 3RK1908-0AP00-0KP0
Base unit (BU30-MS10) With F-DI infeed For ET 200SP motor starter Without infeed Incl. infeed bus cover
-

(Out of stock)
Price on request
Siemens PotDis-BU type P1,dark-colored, PU 1; 6ES7193-6UP00-0BP1
SIMATIC ET 200SP, Potential distributor module, PotDis-BaseUnit, PotDis-BU Typ P1, dark-colored, 17 x P1-potential, 1 x P2-potential, Push-In terminals. P1-, P2-
-

(Out of stock)
Price on request
Siemens BaseUnit Type A1, BU15-P16+A0+2B/T; 6ES7193-6BP00-0BA1
SIMATIC ET 200SP, BaseUnit BU15-P16+A0+2B/T, BU type A1, Push-in terminals, without AUX terminals, bridged to the left, WxH: 15x 117 mm, with temperature acquis
-

(Out of stock)
Price on request
Siemens BaseUnit Type A1, BU15-P16+A0+12B/T; 6ES7193-6BP40-0BA1
SIMATIC ET 200SP, BaseUnit BU15-P16+A0+12B/T, BU type A1, Push-in terminals, with 2x 5 add-on terminals, bridged to the left, WxH: 15 mm x 141 mm, with temperature
-

(Out of stock)
Price on request
Siemens ET 200SP, BU F-DI -forwarding; 3RK1908-0AP00-0JP0
Base unit (BU30-MS9) with F-DI forwarding For ET 200SP motor starter Without infeed
-

(Out of stock)
Price on request
Siemens BaseUnit Type A1, BU15-P16+A0+2D/T; 6ES7193-6BP00-0DA1
SIMATIC ET 200SP, BaseUnit BU15-P16+A0+2D/T, BU type A1, Push-in terminals, without AUX terminals, New load group, WxH: 15x 117 mm, with temperature acquisition
-

(Out of stock)
4.114,78